APPLIANCE DATA

Gas Group
Inlet Pressure
Max Energy Input
Max Gas Rate
Min Energy Input
Pilot Energy Input
Burner Pressure
Main burner flow restrictor
Oxypilot
Gas Inlet Connection
Ignition
Spark Gap
Please see Data label affixed to appliance for current data.
This appliance is for use only with the gas type, and at the pressure stated on the appliance Data
label.
3.0

INSTALLATION REQUIREMENTS

This appliance may be installed with or without a hearth. If a hearth is fitted, the size and design
may be as desired. If the appliance is to be sited near a disused natural draught flue it is recom-
mended that the old flue should be partially sealed off to prevent draughts, however some ventilation
will be required to prevent condensation. The appliance is designed to be wall mounted. It is possible
to install the appliance onto certain types of combustible materials - see section entitled 'Clearances
to combustible materials'.
In the event that the fire is sited near a disused or unserviceable fireplace served by a natural
draught flue, any existing under grate draught device should be sealed off to prevent loss of heat or
creation of draughts. The passageway into the flue should be partially sealed to prevent excessive
draughts, however some ventilation will be required in the old flue to prevent condensation and
dampness. Advice should be sought from your local building control officer.

ROOM SIZING

3.1
X-Fire 1000 models : The room size should be a minimum of 30m 3 (e.g. 11'6" x 11'6" x 8') to
allow adequate circulation of air and ensure the correct operation of the fire.
X-Fire Widescreen models : The room size should be a minimum of 40m 3 (e.g. 13'4" x 13'4" x 8')
to allow adequate circulation of air and ensure the correct operation of the fire.
This volume may include adjacent spaces but these spaces must not be separated by a door. To cal-
culate a room size in cubic metres (m 3 ) divide the room volume in cubic feet (ft 3 ) by 35.3.

SITE REQUIREMENTS

4.0
This appliance is designed to be wall-hung. Do not recess any part of the appliance into the
wall.
This Appliance may be installed in any room in a home, however there are exceptions, and the appli-
ance may not be used in the following rooms;
· Bedrooms - or areas which are mainly used for sleeping.
· Bathrooms - or areas where large amounts of steam are likely to be generated.
Installation in living rooms is common, however other rooms such as kitchens, dining rooms and hall-
ways are permitted, providing a suitable natural gas supply is available, and rooms sizing and venti-
lation requirements are strictly adhered to (see section 4.1).
The appliance is designed to be versatile, and as such will operate correctly when exposed to normal
gentle draughts experienced within the home. It is not recommended, however that the appliance be
X-Fire 1000 models
G20 Natural Gas CAT I2H
20 mbar
Gross
2.6 kW
Net
2.35 kW
0.25 m3/h
Gross
1.5 kW
Net
1.35 kW
Gross
166 W
Net
150 W
High
13.5 mbar. (+/-0.75 mbar). Hot
13.0 mbar. (+/-0.75 mbar). Cold
Low
4.2 mbar. (+/-0.25 mbar). Hot
3.7mbar (+/-0.25 mbar). Cold
Stereo 1.30mm (1/4" BSP)
SIT/Bray 9082
8mm inlet restrictor elbow
Piezo spark
4.0 mm (± 1.0mm)
X-Fire Widescreen models
G20 Natural Gas CAT I2H
20 mbar
Gross
Net
0.34 m 3 /h
Gross
Net
Gross
Net
17.5 mbar. (+/-0.75 mbar). Hot
17.0 mbar. (+/-0.75 mbar). Cold
5.8 mbar. (+/-0.25 mbar). Hot
5.3 mbar (+/-0.25 mbar). Cold
Stereo 1.45mm (1/4" BSP)
SIT/Bray 9082
8mm inlet restrictor elbow
Piezo spark
4.0 mm (± 1.0mm)
2
3.5 kW
3.15 kW
2.0 kW
1.8 kW
166 W
150 W