Akron 3578 STREAMMASTER 설치, 운영 및 유지보수 지침 - 페이지 7
{카테고리_이름} Akron 3578 STREAMMASTER에 대한 설치, 운영 및 유지보수 지침을 온라인으로 검색하거나 PDF를 다운로드하세요. Akron 3578 STREAMMASTER 17 페이지.
E. FAULT CODES
Your StreamMaster monitor comes with built in diagnostic tools. On the controller for stow is a small
LED indicator. The primary function of the LED indicator is to indicate whether the monitor is stowed or
deployed. The LED indicator also functions as a Fault Indicator.
Deployed:
The light will repeatedly flash twice as the unit is deploying. When the fully deployed
position is reached the light will stop flashing and remain on.
NOTE: As soon as the deploy sequence begins, the light in the cab will turn on.
Stowed:
When the fully stowed position is reached the LED indicator will go out.
NOTE: The light in the cab will also go out when fully stowed.
Fault Code 1:
Fault code 1 is represented when the light flashes continually. If the EEPROM on the
circuit board is faulty, Fault 1 will occur.
Correction:
The circuit board must be replaced
Fault Code 2:
Fault code 2 is normal during the deploy sequence and is represented when the light
repeatedly flashes twice. Code 2 is not a fault, but occurs when the deploy button is
pressed and automatically ends when the fully deployed position is reached.
Operation of any switch while flashing twice will cause the monitor to go into E-stop
mode. (See Fault Code 3)
Fault Code 3:
Fault code 3 is represented when the light repeatedly flashes 3 times. This fault code
indicates an emergency stop (E-stops) occurred during stow or deploy. If any switch is
pushed during the stow or deploy sequence all movement will stop and Fault 3 will flash.
Correction:
Operate any switch or press the Stow or Deploy switch to continue the sequence.
Fault Code 4:
Fault code 4 is represented when the light repeatedly flashes 4 times. If the Deploy or
Stow switch is pushed and the monitor is prevented from rotating. Fault 4 will occur.
Correction:
Check for an obstruction by the monitor. Remove the obstruction. Operate any switch
or press the Stow or Deploy switch to continue the sequence.
Fault Code 5:
Fault code 5 is represented when the light repeatedly flashes 5 times. If the Stow or
Deploy switch is pushed and the monitor is prevented from elevating, Fault 5 will occur.
Correction:
Check for an obstruction by the monitor. Remove the obstruction and operate any
switch or press the Stow or Deploy switch to continue the sequence.
Figure 1
3
29
⁄
3 2
2
3
⁄
4
4" 150° Flange
3
1
⁄
" NH Thread
2
L
WARNING
!
5
7
⁄
5
8
Dimensional Specifications
6
1
⁄
8
Elevation
Sensor
21
⁄
3
1 6
16
1
⁄
4
17
⁄
5
3 2
3
⁄
4
Page 7
Range +90° To -45°
90°
8
⁄
1
1 6
L
WARNING
!
3
⁄
9
7
⁄
4
3 2
Rotation Sensor
45°
15
1
⁄
2
12
⁄
3
4