Wiegand
Access
Control Panel
Ground
Data 0
Data 1
LED Out
Beeper Out
It is recommended to install the OSM-2400 near the Wiegand
Access Controller to maximize the OSDP run between the
OSM-2400 and the OSDP Reader, which can be encrypted.
DC Power
Wiegand
Supply
Reader
It is recommended to install the OSM-2400 near the Wiegand
Reader to maximize the OSDP run between the OSM-2400
and OSDP Access Controller, which can be encrypted.
ACU Mode Wiring Diagram
DC Power
Supply
Power
Ground
PD Mode Wiring Diagram
Power
Ground
8 - 16 VDC Input
RS-485
RS-485 +
Ground
Data 0 Output
Ground
Data 1 Output
Strike N.O.
Strike COM
Buzzer Input
Strike N.C.
Ground
Red LED Input
Ground
Green LED Input
8 - 16 VDC Input
OSM-2400
8 - 16 VDC Input
Ground
Red LED Output
Green LED Output
Strike N.O.
Buzzer Output
Strike COM
Strike N.C.
Ground
Data 0 Input
Data 1 Input
8 - 16 VDC Input
OSM-2400
RS-485 –
RS-485 +
Ground
Ground
OSDP
Reader
OSDP Access
Control Panel
RS485 A
RS485 B