6. To verify update completed successfully, navigate to the "About' screen from the user menu as follows.
a. Press and hold the right gray button under the "MENU" item on the bottom right of the screen. The
"MENU" item on the screen will begin to blink several times then stop. Release the button.
b. The "Root Menu" is now displayed. Press the green "Open" button three times to advance the cursor
down so that the "About" item is highlighted.
c. Press and release the right gray button under the "ENTER" item on the bottom right of the screen. This
will display the "About" Screen that has the firmware information on it. Verify 9321 Motor Driver
firmware is at version 1-10 and 9333/9335 is at 1.5.
7. Replace the USB port cover and fasten two screws securely. Do not overtighten.
Update via AkroView
Refer to the
AkroView Diagnostics
the firmware via AkroView.
If you have any questions, please contact the Akron Brass technical support team at
Contact Customer Care PH. 800.228.1161 (330.264.5678) or your Akron Representative for further details
20-03
Firmware Installation and Operations Manual for instructions on how to update