7 STANDARD BACK PANEL FEATURES

1. Line Inputs – Depending on the model, there are either four or eight line inputs available . Line inputs are active bal-
anced with euroblock connectors . If an unbalanced signal is used, connect the unused input pin to ground . Maximum input level
is +20dBu = FS (full scale) .
2. Line Outputs - Depending on the model, there are either four or eight line outputs available . Line outputs are servo-
balanced with euroblock connectors, and may be wire balanced or unbalanced, with a maximum output level of +20dBu FS .
3. 12V Digital Logic I/O - All models have a nine pin euroblock connector for logic inputs or outputs . The Logic I/O tab
in software allows logic pins to be assigned as either logic inputs or logic outputs . Logic input "high" range is from +2 .3VDC
to +25VDC (do not exceed +25VDC) . Logic inputs can be assigned to trigger a preset recall or push-to-talk mic function from
contact closure . Logic pins can also be assigned as current-limited 12V logic outputs, triggered by a preset recall or WR-5 button
for control of 12V or 5V external devices . See page 11 for more logic pin details .
4. 5VDC Remote Level Control - All models have a 10 pin euroblock connector for accommodating up to eight user
defined remote DC level controls. Use an Ashly WR-1 remote attenuator (or equivalent 10K potentiometer), along with a remote
gain block placed within the software DSP section to assign remote level control to any channel's input or output section . Wire
the 5VDC Remote Control ground to the CCW pin of the remote control potentiometer, wire +5 to the CW pin, and wire the
control pin (1-8) to the potentiometer wiper .
5. Ethernet Jack - This is the RJ-45 connector used for 10/100 ethernet control . Maximum cable distance to the nearest
computer, hub, or switch using CAT5 twisted pair copper cable is 100 meters .
6. RS-232 Jack - This connector is for remote control by non-Ethernet based hardware that uses RS-232 control data
protocol . A complete NE RS-232 protocol document is available on the Ashly website .
7. Remote Data - This is used to connect a remote WR-5 programmable button controller or RD-8C fader controller .
8. Word Clock - If two pieces of digital audio gear need to be synchronized, i.e. their sample rates are very slightly
different and must be made to match exactly, word clock synchronization is necessary to avoid sample skipping. Additionally,
when several pieces of gear are cascaded in an AES3 digital audio chain, each digital audio input adds some small amount of
clocking jitter and perhaps sample delay . After several units, the cumulative jitter could cause a loss of lock (and hence loss
of audio), increased distortion due to large amounts of jitter, or even a small delay . By connecting a master word clock to each
device, they all become precisely synchronized.