Cypress Suprex SPX-7410 운영 매뉴얼 - 페이지 10

{카테고리_이름} Cypress Suprex SPX-7410에 대한 운영 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Cypress Suprex SPX-7410 18 페이지. Reader extender - fiber optic interface

Cypress Suprex SPX-7410 운영 매뉴얼
Note: The LED and Door Strike operation of the FO Suprex® differs from previous Suprex® version
To activate the relay on the Remote unit, connect as shown below. These connections can be used to allow the
Remote relay to operate a DOOR STRIKE, GATE, or other locking hardware. Refer to following pages in this
document for details of each I/O operation and connection.
There are two relays available for accessory outputs at the Remote end. Either relay can be used to provide the
Door Strike or Gate activation function. This example uses Relay 1.
Only Relay and LED Connections are shown for clarity, refer to previous diagrams for Power and Data connections.
Cypress Suprex® F.O. Series - Door Strike and LED I/O
Wiring Example - Door Strike Follows LED
Access
Control
Panel
Wiring Example - Door Strike does not follow LED
Access
Ground
Control
Panel
N.O.
Strike Signal
Com
Ground
LED Signal
LED Signal
Ground
Ground
Suprex Central
R1 Input
Controls
Strike on
Remote
LED In
R1 IN
Ground
Suprex Central
Ground
LED In
R1 Input
R1 IN
Controls
Strike on
Remote