ACR Electronics GlobalFix 406 제품 지원 매뉴얼 - 페이지 8

{카테고리_이름} ACR Electronics GlobalFix 406에 대한 제품 지원 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. ACR Electronics GlobalFix 406 13 페이지. Emergency position indicating radio beacon fcc type accepted
ACR Electronics GlobalFix 406에 대해서도 마찬가지입니다: 제품 지원 매뉴얼 (16 페이지)

ACR Electronics GlobalFix 406 제품 지원 매뉴얼
Prod. No.
Model No.
2742
RLB-35
2744
RLB-35
te:
All models above conform to Class 1 Requirements
(operations: –40°C to 55° C storage: -50°C to 70°C)
1.4
AUTHORIZATIONS
1.4.1
The GlobalFix™ 406 EPIRB meets the requirements of Federal
Communications Commission (FCC) Part 80 (Product No. 2742,
2744) and GMDSS (Product No. 2742)
1.5
CHARACTERISTICS
1.5.1
The GlobalFix™ 406 EPIRB is a floatable, battery operated unit.
The beacon case, with its external antenna, is waterproof. The
semiconductor circuits are mounted within the case assembly that
also contains the battery power supply. A "Test/On" switch is
installed on top of the beacon, along with a strobe light. The
beacon must be stored in its special mount, free of obstructions
aboard a vessel for automatic float-off. The unit is self-buoyant and
no external floatation devices are required.
1.6
TECHNICAL DATA - GlobalFix™ 406
1.6.1
Applicable Documents
RTCM
Standard for 406 MHz Satellite EPIRBs
COSPAS-SARSAT
Document C/S T.001 Oct. 99
FCC
Part 80 (Model No. RLB-35) and
GMDSS (Product No. 2742)
Cat. I
Cat. II
X
X
Y1-03-0157 Rev. T1
8
4.3
The hydrostatic release unit (HRU) must be replaced by the date
indicated on the float free mounting bracket. The hydrostatic
release can be replaced by removing the Beacon from the
bracket, then sliding the hydrostatic release assembly out of the
keyed opening on the spring and mounting bracket. Insert the
new hydrostatic release assembly, in place by engaging it to the
opening of the ejection spring and case. When servicing the
HRU, ACR strongly recommends replacing the entire hydro-
static assembly, including hydrostatic release, release rod and
all hardware (P/N 9367). Always use original ACR replacement
parts. Use of unauthorized replacement parts may void your
warranty. Place beacon into the mounting bracket, and replace
cover, securing in place with hitch pin going through the hydro-
static release rod.
4.4
The battery (P/N 1096) must be replaced by the date indicated
on the beacon. At each inspection, check the time remaining
until replacement is required.
NOTE: There are no user serviceable items inside the EPIRB.
DO NOT OPEN THE EPIRB UNLESS TO DISABLE IN
CASE OF FAULTY ACTIVATION.
Refer all long life battery replacement and other internal EPIRB
service to a factory authorized service center.
For the nearest location of a factory authorized service center,
call 1-800-432-0227 Ext. 112 (toll free).
4.5
The GlobalFix™ 406 contain lithium batteries which are not
subject to the requirements of the DOT Subchapter C, Haz-
ardous Materials Regulations, because they meet the United
Nations Classification of LiS02 Batteries for Shipment of "Non
– Dangerous".
5.0
REGISTRATION
5.1
It is imperative that this EPIRB be registered with NOAA
(National Oceanic and Atmospheric Administration) in the USA
or with your own national authority.
The EPIRB has been programmed with a unique identification
Y1-03-0157 Rev. T1
17