Configure the Drivers
6.8. By default, all driver types in the Configure Local Parameters pane are set to CapSense
Slider Sensor. To setup the LEDs, set the Pin Type for drivers C0 through C3 to GPOutput
and the Drive Mode for each of those drivers to Strong Drive.
To setup the mechanical button, set the Pin Type for driver G4 to GPInput. Set the Drive
Mode to Open Drain Low.
Configure Slider and LED Behavior
6.9. In the Pin Specific Tuning pane, choose G0 from the Select Pin menu.