Asian Resources Int'l Limited T2 Turgo 사용 및 관리 지침 매뉴얼 - 페이지 15

{카테고리_이름} Asian Resources Int'l Limited T2 Turgo에 대한 사용 및 관리 지침 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Asian Resources Int'l Limited T2 Turgo 18 페이지. Micro-hydroelectric generator

a) Start the generator and adjust the spear valve to obtain 220-240 volts, 0 amps at the
panel. [Do not turn the circuit breaker on].
b) Adjust the potentiometer on the circuit board very slowly to the left. When you
detect a small decrease in voltage, stop. Turn on the circuit breaker and increase water
to increase power to the unit. Increase power until a load of 2kW is indicated (P =VI).
c) If adjusting the potentiometer does not correct the problem, then contact PowerPal.
The problem is probably with the potentiometer.

TECHNICAL SPECIFICATIONS

1 Rated power output
2 Maximum allowable load
3 Intended voltage
4 Frequency at rated power output
5 Frequency at runaway speed
6 Runaway speed
7 Height
8 Weight
9 Turbine runner type
10 Runner diameter
11 Number of buckets
12 Number of nozzles
13 Generator
14 Generator insulation
15 Protection grade
16 Load controller circuit breaker
17 Upper generator bearing size
Lower generator bearing size
Turbine bearing size
18 Seal size
19 Recommended cable
20 Operating temperature
21 Operating humidity
Notes:
1,2.
Rated power output is the manufacturer's specified output for the given head
and flow conditions. A higher output is possible if the head is greater or the flow is
faster than recommended. If the maximum allowable load is exceeded then permanent
damage to the stator may occur.
3.
Is approximately 220V when the ELC is used.
5,6.
Runaway speed is the speed of the rotor if no load is applied. This speed is
reduced under load.
18.
We recommend SKF brand or similar high quality bearings.
Also, the diagrams and much useful information on pages 7 and 16 are taken from
Micro-hydropower Sourcebook – A Practical Guide to Design and Implementation in
Developing Countries. NRECA, 1986.
MHG-T2
2000W
2200W
220V~
50 Hz
70 Hz
1500rpm
600mm
90kg
Turgo
270mm
20
1
3- phase
Class B
IP54
20A
6206-2Z
SKF 7206B
SKF 1207
38x58x10mm
4mm2
5 to 50 ° C
0 to 90%
PowerPal™ T2 Turgo 15