AsiaPower IND600 사용자 설명서 - 페이지 2

{카테고리_이름} AsiaPower IND600에 대한 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. AsiaPower IND600 2 페이지.

Features
Line interactive design
Boost and buck AVR (Auto voltage
regulation)
Cold start function (DC power on)
Model
Input
Capacity
Voltage
Frequency
AVR
Generator Compatible
Connection
Output
Voltage on mains
Frequency on mains
Voltage on Battery
Freq on Battery
Waveform
Power Factor Lagging
Efficiency
Sockets
Protection
O/p Short cct
O/p overload shutdown
Transfer Time
Mains to Inverter
Battery
DC Bus
Internal Battery
Proctection
Typical Recharging Time
Backup time on PC
with LCD monitor
Indications
Power ON
Inverter ON
Alarm
Battery Backup
Battery Low
Overload
Environment
Ambient Operation
Audible Noise
Physical
Storage Condition
Weight (Kgs.)
Dimension - WxDxH (mm)
Specification subject to change without prior intimation
ASIA POWERCOM PVT. LTD.
H.O.: 401, 402 4th Floor,Arya Arcade CHS, Station Road, Vikhroli West , Mumbai - 400083.
keeping your technology alive
[email protected][email protected] • www.asiapowercom.com
Specifications - IND600

Advanced battery management

(ABM technology)

Battery charging in UPS OFF Mode
Microprocessor controlled
IND600
1 PC Load (max 600VA)
230V
40-65Hz
140V-300V
3 Pin 10A, Indian Plug, 1.2 mt wire
230V +10%~-15%
Follows Input
230V ±10%
50 Hz ±1%
Modified Sinewave
>80%
3 output sockets
UPS output cutoff immediately
110% for 1 min
130% for 3 sec
4-8 ms
7AH, SMF
Auto Discharge Protection
6 hrs (to 90% full capacity)
approx. 10-15 mins
LED steady
LED blink
Slow beeping sound (about 0.47 Hz)
Rapid beeping sound (about 1.8 Hz)
Continuos beeping sound
0-40°C, 0-95% humidity non condensing, 3500 meter max.
<40DbA (1 meter from surface)
15,000 meter max. elevation
4.2 Kgs.
101 x 279 x 142
Yes
0.6
12V
TROUBLESHOOTING
Use the table below to solve minor UPS
installation or operation problems. If any
abnormal situation occur that are not
listed above, please call service people
immediately.
Error/Problem
Possible cause
Remedy
No LED
Battery defect.
Charge battery
display
up to 8 hours.
on the
Replace with the
front panel.
same type
of battery.
Power switch is
Press the power
not pressed
switch again.
.
Alarm buzzer
Overload of
Verify that the
beeps
the UPS.
load matches the
continuously
UPS capability
when AC
specified in the
supply is
specs.
normal.
When Power
Overload of
Remove some
failure, backup
the UPS.
noncritical load.
time is
shortened.
Battery voltage
Charge battery
is too low.
16 hrs. or more.
Battery defect
Replace with the
due to high
same type of
temp. operation
battery.
environment, or
improper
operation
of battery.