ACR Electronics ResQFix PLB-300 제품 지원 매뉴얼 - 페이지 7
{카테고리_이름} ACR Electronics ResQFix PLB-300에 대한 제품 지원 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. ACR Electronics ResQFix PLB-300 15 페이지. Gps personal locator beacon
ACR Electronics ResQFix PLB-300에 대해서도 마찬가지입니다: 제품 지원 매뉴얼 (15 페이지)
3.2
Reporting of False Alerts
A false alert must be reported to the nearest search and rescue authorities. The information reported must
include the beacon Unique Identifier Number (UIN), date, time, duration and cause of activation, as well as
location of beacon at the time of activation. If the beacon is registered outside of the United States, contact
your national authority.
United States Air Force Rescue
Coordination Center (AFRCC)
False alerts that are rectified must be reported to the AFRCC to let them know that the situation has been
corrected and everything is fine. Responsibly reporting these events to the AFRCC or your proper authority will
not incur a penalty, but deliberate misuse or not notifying the proper authority may incur a severe penalty.
TO REPORT FALSE ALERTS WORLDWIDE, CONTACT THE NATIONAL AUTHORITY WHERE YOUR
BEACON IS REGISTERED.
SECTION 4 – OPERATION
The ResQFix™ and MicrOFix™ 406 GPS beacon models are designed to be manually deployed and
activated. They are only to be activated when all other means of self-rescue have been exhausted. When
properly registered as required, the activation of the beacon tells Search and Rescue who you are, where you
are, and that you are facing a life threatening situation.
ON / OFF Button
Self Test / GPS Test
Button
NOTE: If you notice the PLB is flashing the red or green LED and BEEPING periodically on its own, this
likely means it has accidentally been activated and needs to be shut off and reported.
Y1-03-0228 Rev. C
Tel: 1-800-851-3051
Figure 2 - Key Pad Functions
Activation Diagram
When activated:
(Red LED) 406 MHz Only
(Green LED) 406 MHz
includes GPS data
(IR LED) Programming Interface
(Not owner accessible)
6