Before using the machine:

Open oil plug item 4 and pour in oil from oil ampul in the machine box.
Do not exert undue pressure on the machine. This will not increase its performance. Just position the bit and guide it
into the hole.
Placing the machine into the box
Make sure the adjusting sleeve is locked at the setting "rotary hammer drilling".
Side handle
This can be turned through 360°and clamped in any desired position.
Depth gauge
Press unlock button, adjust the depth gauge and release button.
Lubrication of shank end
Occasionally clean shank ends and spray sparingly with lubricant sprayer. Do not spray into the chuck.
Fig. 1
Fig. 1: Drilling in explosive surroundings
The drill must be water cooled to avoid sparks.
Fig. 2: Rotary hammer drilling
Pull back the adjusting sleeve and turn it clockwise to lock. Do not use the quick-release chuck at this setting because
drills and tools will be damaged.
Fig.3: Pull back the locking sleeve and insert the drill. Turn the locking sleeve until it snaps back into the outset
position. Press the machine against the work surface before switching on otherwise the tool will not hammer. If the drill
sticks in the hole, withdraw and reinsert it several times when drilling.