d&b audiotechnik 12S-SUB 매뉴얼 매뉴얼 - 페이지 6
{카테고리_이름} d&b audiotechnik 12S-SUB에 대한 매뉴얼 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. d&b audiotechnik 12S-SUB 9 페이지.
Fig. 4: Installing the fixed cable connection
Fig. 5: NL4 cable connection with cover plate [1]
6
1. Prepare the rubber grommet and the connection cable.
2. Remove the knockout opening in the cover plate and attach
the rubber grommet correspondingly.
3. Insert the connection cable through the rubber grommet and
connect the cable wires to the screw terminal.
Þ Observe the correct polarity!
4. Undo the four screws of the connector panel.
5. Push the cover plate towards the connector panel until it fits
into place.
6. Finally fix the cover plate together with the connector panel
using the four screws.
NL4 connection with cover plate
The two NL4 connector sockets of the cabinet's connector panel
are located in a recess to allow the use of the cover plate [1]
together with NL4 cable connectors, as shown in the graphic
opposite.
Note: Neutrik NL4FC type connectors must be used for this
option.
The cover plate is equipped with two knockout openings to allow
daisy chaining of the loudspeaker.
To use the NL4 connection, proceed in the same manner as
described above in the section entitled Þ "Fixed cable connection"
on page 5.
2.3. Operation
NOTICE!
Only operate d&b loudspeakers with a correctly configured d&b
amplifier, otherwise there is a risk of damaging the loudspeaker
components.
Operation with D6 or D12
Select the controller setup 12S-SUB.
d&b 12S-SUB Manual (1.3 EN)