d&b audiotechnik Ci60 매뉴얼 - 페이지 6

{카테고리_이름} d&b audiotechnik Ci60에 대한 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. d&b audiotechnik Ci60 10 페이지. Flying bracket
d&b audiotechnik Ci60에 대해서도 마찬가지입니다: 매뉴얼 (10 페이지), 설치 지침 (11 페이지)

d&b audiotechnik Ci60 매뉴얼
Fig. 4: Frequency response correction of
CPL circuit
DELAY ON
REMOTE
LO IMP
ON
1
2
3 4 5 6
7
8
SPKR
HFA
CUT
Fig. 5: E-PAC Configuration for Ci60/Ci90
(E-PAC version 2)
Ci45/Ci60/Ci90 Manual
CPL circuit
The CPL (Coupling) circuit compensates for coupling effects between the
cabinets when building closely coupled arrays. CPL begins gradually at
1 kHz, with maximum attenuation below 250 Hz, providing a balanced
frequency response when cabinets are used in arrays of two or more.
The function of the CPL circuit is shown in the diagram opposite and can
be set in dB attenuation values between –9 and 0, or a positive CPL
value which creates an adjustable low frequency boost around 65 Hz (0
to +5 dB).

Operation with E-PAC

To drive Ci60/Ci90 or Ci45 loudspeakers, select the controller setup
Ci60/Ci90 (CI6/CI9 - possible with E-PAC version 2 from serial number
Z2500.000.02-01313 and E-PAC version 3) or the Ci45 setup (possible
with E-PAC version 3).
For an E-PAC version 2, the setup is selected by setting the appropriate
DIP switches on the rear panel.
For an E-PAC version 3, the respective setup can be selected via the
encoder in conjunction with the LCD.
Selecting Ci45/Ci60/Ci90 mode enables the E-PAC to drive one
Ci45/Ci60/Ci90 loudspeaker. LO IMP mode configures the E-PAC to
drive a maximum of two loudspeakers with a 6 dB reduction in input
level to the loudspeakers.
The CUT and HFA settings are available on versions 2 and 3 and are
explained in the previous section "Operation with D6 or D12 -
Controller settings".
(9.2 EN)