d&b audiotechnik Vi-SUB 매뉴얼 - 페이지 7

{카테고리_이름} d&b audiotechnik Vi-SUB에 대한 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. d&b audiotechnik Vi-SUB 11 페이지.

d&b audiotechnik Vi-SUB 매뉴얼
d&b Vi-SUB Manual 1.4 en
d&b SenseDrive
The SenseDrive feature within D12 amplifiers enables electrical
compensation for the properties of the loudspeaker cable used.
SenseDrive requires an additional sense wire. SenseDrive is
therefore only available with EP5 connectors and 5-wire cabling
for applicable loudspeakers.
Note: When the D12 is operated in "Mix TOP/SUB mode",
the SenseDrive function is only available at the output B
connector.
In permanent installations, SenseDrive can also be applied to
cabinets with NL4 connectors or the fixed cable option (PG). The
connection of the negative signal wire (EP5 pin 4 of the respective
D12 output) to the SenseDrive wire (EP5 pin 5 of respective D12
output) is made in a breakout box close to the loudspeaker
cabinet. For an uncompromising SenseDrive performance the
connection should be done not more than 3 m (10 ft) away from
the loudspeaker.

2.3 Operation

NOTICE!
Only operate d&b loudspeakers with a correctly configured d&b
amplifier, otherwise there is a risk of damaging the loudspeaker
components.
Applicable d&b amplifiers:
30D/D12/D20/D80.
Application
Setup
Vi-SUB
V-SUB
Within applicable d&b amplifiers, the controller setup is available
in Dual Channel or Mix TOP/SUB mode.

2.3.1 Controller settings

For acoustic adjustment the 100 Hz mode can be selected.
100 Hz mode
With the 100 Hz mode selected, the upper operating frequency of
the system is reduced from 115 Hz to 95 Hz.
It can be used when actively driven Vi subwoofers are used to
supplement Vi cabinets operated in full range mode. The 100 Hz
mode can also be used to compensate for the effect of close
coupling between the Vi-SUB and Vi cabinets operated in CUT
mode. With Ti cabinets the standard mode is recommended.
Cabinets per
channel
2
7