Asko TD70.1 SPO 설치 지침 매뉴얼 - 페이지 10

{카테고리_이름} Asko TD70.1 SPO에 대한 설치 지침 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Asko TD70.1 SPO 12 페이지. Domestic vented tumble dryer

Asko TD70.1 SPO 설치 지침 매뉴얼
Installation instructions
Power Supply Cord
You will need a 4-wire power supply cord with
four No. 10 copper wires and a matching 4-wire
receptacle of NEMA Type 14-30R, as illustrated
below. The fourth wire must be identifi ed with
a white cover and the ground conductor by a
green cover.
To connect a 4-wire power cord to the dryer,
follow the steps below.
NOTE!
The numbers in the illustration correlate to the
step numbers.
1. Turn the power off at the breaker/fuse box.
2. Remove terminal block cover.
3. Use the strain relief attached below the
terminal block opening.
4. Remove center terminal block screw.
6
5. Remove ground wire (green with yellow
stripes) from external ground connector
screw and remove from center terminal
block.
6. Connect ground (green) wire of cord to
external ground conductor screw.
7. Connect neutral (white) wire of cord under
center screw of terminal block.
8. Connect the other wires to outer screws.
9. Tighten the strain relief screws.
10.Replace terminal box cover on back of dryer.
11.Plug dryer into wall receptacle.
12.Turn power on at breaker/fuse box.
10
4
7
8
Customer Care Center
1-800-898-1879