ACR Electronics RCL-100 제품 지원 매뉴얼 - 페이지 17
{카테고리_이름} ACR Electronics RCL-100에 대한 제품 지원 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. ACR Electronics RCL-100 20 페이지. Remote controlled search light
ACR Electronics RCL-100에 대해서도 마찬가지입니다: 문제 해결 및 부품 교체 매뉴얼 (17 페이지)
8.0
BULB REPLACEMENT
Two 55W, quartz-halogen bulbs are provided with your RCL-100D. If they should need
replacement, they must be ordered through ACR Electronics, by P/N A1-14-0080-1 (12V units)
or A1-14-0080-2 (24V units).
To replace the lamps:
1.
Disconnect unit from power source and allow bulbs to cool.
2.
Remove two screws holding the front flange and glass in place.
3.
To remove the old lamp bulbs, grasp base of the lamp and pull straight out. DO NOT
TOUCH GLASS PARABOLIC REFLECTORS WITH FINGERS OR TOOLS!
4.
Install the new lamp bulb using a soft clean cloth to avoid touching the bulb with your
fingers. Insert the lamp bulb pins into socket and press firmly in place.
NOTE: If the Lamp Bulb or Reflectors are accidentally touched, carefully clean with
a soft rag and alcohol before continuing.
5.
Replace the front flange and glass and install the two retaining screws. Be sure the
neoprene gasket is securely in place.
6.
Reconnect the unit to the power source.
9.0
RCL-100D SEARCHLIGHT COMPONENTS
PRODUCT NO. 1930.3 - RCL-100D 12 V Searchlight Installation Kit includes:
Description
Searchlight, RCL-100D, 12 V
Kit, Nylon Washers (4)
Connector, "F"
Cable, Coaxial
Master Controller, URC-102
Connector, "In-Line"
Point Pad™, URP-102 with
Surface Mount Case
Case, Flush Mount
Gasket, Surface Mount
Gasket, Flush Mount
U Clamp
Nuts, Nylon-lock
Washers
Warranty Card
Product Support Manual
Mounting Templates
PRODUCT NO. 1931.3 - RCL-100D 24 V Searchlight Installation Kit includes:
Quantity
1
1
2
15'
1
8
1
1
1
1
2
2
2
1
1
1
15
ACR Part Number
A3-06-1106-3
A3-06-1940
A1-03-0220
A2-07-0002-6
A3-06-2231
A1-03-0222
A3-06-2230
A1-18-1875-2
A1-25-0140-1
A1-25-0140-2
A1-17-1366
A1-05-0776
A1-05-0777
A1-20-1019
Y1-03-0138
Y1-03-0138-1
Y1-03-0138 Rev. K