Asko HG13 series 설치 매뉴얼

{카테고리_이름} Asko HG13 series에 대한 설치 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Asko HG13 series 2 페이지.

Asko HG13 series 설치 매뉴얼
Installation instructions
Gas hobs
The fitting of the appliance should only be carried out by a authorised person/licensed gasfitter. Please read the safety regulations.
See the data plate for information regarding the total gas consumption, gas type and gas pressure.
Preparations for installation
Pictograms used
Important information
Gas connection
Electrical connection
05
1/2" ISO 228 / 1/2" ISO 7-1
The gas connection must comply with national and local regulations.
The hotplate can be connected with rigid pipe as specified in
AS/NZS 5601.1current edition.
When the appliance is connected with a hose assembly,
the supply point shall be accessible with the appliance installed.
A
A (mm)
B (mm) C (mm) D (mm) E (mm)
HG11
1114
412
48
HG13
330
522
48
HG16
644
522
45
HG18
794
522
45
HG19
904
522
45
oven
E
B
C
48
387
48
75
45
69
31
440
45
517
Accessibility!
Free space around appliance
Rangehoods and exhaust fans shall be
installed in accordance with
manufacturers instructions.
For an overhead exhaust fan A>750 mm!
A (mm)
B (mm) C (mm) D (mm)
HG11
min. 650 min. 900 min. 450 min. 120
HG13
min. 650 min. 600 min. 450 min. 120
HG16
min. 650 min. 600 min. 450 min. 120
HG18
min. 650 min. 750 min. 450 min. 120
HG19
min. 650 min. 900 min. 450 min. 120
This appliance must be earthed
The electrical connection must comply with national and local regulations.
F
D
E
E/F
C
A (mm)
HG11
600
HG13
600
HG16
600
HG18
600
HG19
600
y
>60º C
<60º C
x
C
240 V - 50 Hz - max. 20 W
A
H
G
B
D
B (mm)
C (mm)
D (mm)
E (>mm) F (>mm) G
1070
380
60
30
50
290
490
60
30
50
560
490
60
30
50
750
490
60
30
50
860
490
60
30
50
Y:
metal
y
Gas supply valve
shall be accessible
oven
x
B
A
D
H
55
100
55
100
50
100
50
100
50
100
X:
safety hose
Gas supply valve
shall be accessible