2.3 Sensor Placement
1. Place the sensor in the pool or spa within 100 feet of the display console (Figure 11,
reference A). Avoid transmitting through solid earth or ground (Figure 11, reference B).
Use a tether (string) to fix the sensor in the pool or spa.
2. Place the console at least three feet away from computers, TVs and wireless phones.
3. Avoid transmitting through solid metal barriers.
NOTE: The F007PF is designed to float. If the F007PF is used under a cover and the sensor is
constantly submerged, the additional pressure will lead to premature gasket failure. Moisture will
enter the sensor compartment and cause sensor failure.
4 Maintenance
During each battery change (1-2 years), we recommend applying waterproof silicon grease to the
Version 1.5