3.6 Combustion Fan Assembly
Step 1 Slacken jubilee clip and remove the
flexible hose from the fan.
Step 2 Remove fan screws and unplug from
burner box.
Step 3 The combustion fan can now be
detached.
Step 4 Remove the fan orifice plate spigot and
spinning.
Step 5 Inspect the impeller and remove any
dust with a soft brush.
Step 6 Remove any dust from fan scroll and
from around the motor.
Step 7 Ensure the impeller rotates freely.
Step 8 Refit components.
3.7 Radiant Tube Servicing
Step 1 Brush any dust from the exterior of the
tubes.
Step 2 Inspect the fan and burner tubes visually.
If the tubes appear clean, skip to servicing the
reflector.
Step 3 Remove the U bend.
Step 4
Withdraw the turbulators from the
appliance. Carefully noting their condition and
position. Replace turbulators if necessary.