PART D.

BATTERY INSTALLATION AND REPLACEMENT

Two 3.6V Lithium thionyl Chloride batteries, AA-size (7400-0011) are included with the Totalizer.
NOTE: THE 8150 WILL NOT OPERATE WITH STANDARD 1.5V ALKALINE BATTERIES. USE 3.6 V
LITHIUM BATTERIES ONLY!
Observe Polarity! Note that both batteries should face the same direction.
When the 'low battery' indicator appears on the display, both batteries should be
replaced within 90 days.
Remove and replace battery #1 first, then remove and replace battery #2.
This ensures that all settings and totalizer values are saved.
If the low battery symbol reappears for more than 10 seconds after installing new
batteries, one battery is reversed, or battery #2 was installed before battery #1.
Secure the batteries by fastening the hook-and-loop straps.
AMBIT
INSTRUMENTS PTY LTD
ABN 50 005 613 641
DISPOSE OF EXPENDED BATTERIES PROPERLY!
Lithium batteries contain hazardous chemicals.
Dispose of batteries according to local regulation.
Office & Factory | 42 Titan Drive, Carrum Downs, Victoria, 3201.