AMC DT15 Installation - Page 4

Browse online or download pdf Installation for Security Sensors AMC DT15. AMC DT15 4 pages. Dual technology curtain lens intrusion detector

AMC DT15 Installation
SpecIfIche tecnIche / SpecIfIcatIonS / SpecIfIcatIonS technIQueS
DT15
Alimentazione / Input Voltage
Consumo / Current Drain (Alarm/Stand-By)
Grado di Protezione IP / IP Grade
Portata in lunghezza / Coverage
Portata in larghezza / Angle
Piroelettrico / PIR
Microonda / Microwave
Massima potenza irradiata / Max. Radiated power
Caratteristica del segnale emesso / Type of Emitted Signal
Lente (fasci e livelli) / Lens (beams and levels)
Durata allarme / Alarm period
Tipo allarme / Alarm type
Antiapertura / Anti-opening
Antistrisciamento / Creep Zone
Contatto di allarme / Alarm's Contact
Contatto di tamper / Tamper Switch
Temperatura di esercizio / Operating Temperature
Temperatura di stoccaggio / Storage Temperature
RFI Protezione / Protection
Led WALK TEST (MW and PIR)
Cover / Housing
Accessori / Accessories
Dimensioni / Dimensions
meets the requirements/conforme ai requisiti:
en50131-2-4:2008
en50131-2-4 : grade 2
en50131-2-4 : environmental class III
ceI 79-2: I level
Tutti i ns. prodotti sono conformi ai requisiti richiesti dalla norma CEI 79-2 ed. 1998 + AB 2000.
L'installazione deve essere eseguita a regola d'arte da personale specializzato.
Il costruttore declina ogni responsabilità nel caso in cui il prodotto venga manomesso da persone non autorizzate.
Si raccomanda di verificare il corretto funzionamento del sistema d'allarme almeno una volta al mese, tuttavia un sistema
di allarme elettronico affidabile non evita intrusioni, rapine, incendi o altro, ma si limita a diminuire il rischio che tali situa-
zioni si verifichino.
Il Costruttore dichiara, in conformità alla direttiva 99/05/CE (R&TTE), che il sensore mod. DT15 soddisfa i requisiti della
norma EN60950-1.
Our products/systems comply with the essential requirements of EEC directives.
Installation must be carried out following the local installation norms by qualified personnel.
The manufacturer refuses any responsibility when changes or unauthorized repairs are made to the product/system.
It is recommended to test the operation of the alarm product/system at least once a month. Despite frequent testing and
due to, but not limited to, any or all of the following: tampering, electrical or communication disruption or improper use, it
is possible for the product/system to fail to prevent burglary, rubbery, fire or otherwise. A properly installed and maintained
alarm system can only reduce the risk that this happens.
The Manufacturer declares, in accordance with Directive 99/05/CE (R & TTE), the sensor mod. DT15 meets the requirements
of standard EN60950-1.
www.amcelettronica.com
DT15 Dual Technology - v 1.0
9 to 15 Vdc
(22 mA / 22mA) @ 13.8 Vdc
IP42
5 m
90°
2 elementi / 2 elements
DRO freq. 2.45 GHz
10 mW
Continuo / Continuous
5 patterns on 1 levels
4 sec.
AND
100 mA - 40 V - 16 Ω
Max 40 mA - 30 Vdc
From -25 °C to +55 °C
From -20 °C to +60 °C
10 V / m (20 /1000 MHz)
ABS
110 x 60 x 46 mm
installation instructions