TECHNICAL FEATURES / SPECIFICHE TECNICHE
AMC PRO MASK
Input Voltage / Alimentazione
Current Drain / Consumo (Alarm / Stand-By)
Tipical Voltage / Tensione nominale
Coverage / Portata Massima
Aperture Angle / Angolo di Apertura
PIR / Piroelettrico
Lens / Lente
Microwave frequency / Frequenza Microonda
Alarm period / Durata allarme
Alarm Type / Tipo allarme
Anti-opening / Antiapertura
Back Tamper / Antistrappo**
Anti masking/ antimascheramento**
Alarm Contact / Contatto di allarme
Tamper Switch / Contatto di Tamper
Operating Temperature / Temperatura di esercizio
Storage Temperature / Temperatura di stoccaggio
RFI Protection / Protezione RFI
Walk Test LED (MW and PIR)
Housing / Cover
Dimensions / Dimensioni
* Certificazione : 10 V/m (80/1000 MHz) ** Non certificato
Meets the requirements:
Conforme ai requisiti:
R&TTE 99/5/CE
EN 50131-2-4: 2008
EN 50131-2-4 Grade 2
EN 50131-2-4 Class 2
CEI 79-2: I° Level
Prodotto conforme alla Direttiva 99/5/CE. La dichiarazione di conformità è disponibile presso la nostra sede.
Tutti i ns. prodotti sono conformi ai requisiti richiesti dalla norma CEI 79-2 2°ed. 1998 + Ab 2000.
L'installazione deve essere eseguita a regola d'arte da personale specializzato.
Il produttore declina ogni responsabilità nel caso in cui il prodotto venga manomesso da persone non autorizzate.
Si raccomanda di verificare il corretto funzionamento del sistema d'allarme almeno una volta al mese, tuttavia un sistema
di allarme elettronico affidabile non evita intrusioni, rapine, incendi o altro, ma si limita a diminuire il rischio che tali situa-
zioni si verifichino.
This product comply the 99/5/CE directive. The declaration of conformity is available at our offices.
Our products/systems comply with the essential requirements of EEC directives.
Installation must be carried out following the local installation norms by qualified personnel.
The manufacturer refuses any responsibility when changes or unauthorized repairs are made to the product/system.
It is recommended to test the operation of the alarm product/system at least once a month. Despite frequent testing and
due to, but not limited to, any or all of the following: tampering, electrical or communication disruption or improper use, it
is possible for the product/system to fail to prevent burglary, rubbery, fire or otherwise. A properly installed and maintained
alarm system can only reduce the risk that this happens.
www.amcelettronica.com
Promask Dual Technology ver. 1.2
9 to 15 V
32 mA / 29 mA @ 13.8V
13.8V
20mt
90°
2 Elements / 2 Elementi
Fresnel (22 Patterns on 3 levels)
9.3 GHz / 9.9 GHz / 10,525 GHz
2 sec.
AND - OR - AUTO OR
✔
✔
✔
100 mA - 40 V - 2.5 -16 Ω
Max 40 mA - 30 Vdc
From -10 °C to +55 °C
From -20 °C to +60 °C
30 V / m (80 /1000 MHz)*
✔
ABS
130 x 66 x 38.5 mm