LENS
VISTA LATERALE
Copertura minima
Copertura massima
SPECIFICATIONS
SMILE 19
Alimentazione / Input Voltage
Consumo / Current Drain
Portata in lunghezza / Coverage
Portata in larghezza / Angle
Piroelettrico / PIR
Lente / Lens
Antiapertura / Anti-opening
Antistrisciamento / Creep zone
Contatto di allarme / Alarm contact
Contatto di tamper / Tamper switch
Temperatura di esercizio / Operating temperature
RFI Protezione / Protection
Led WALK TEST
WALK TEST IN
Cover / Housing / Boiter
Dimensioni / Dimensions
Meets the requirements: EN 50131-2-2 Grade 2 EN 50131-2-2 Class 2
L'installazione deve essere eseguita a regola d'arte da personale specializzato.
Il produttore declina ogni responsabilità nel caso in cui il prodotto venga manomesso da persone non autorizzate.
Si raccomanda di verificare il corretto funzionamento del sistema d'allarme almeno una volta al mese, tuttavia un sistema di allarme elettronico
affidabile non evita intrusioni, rapine, incendi o altro, ma si limita a diminuire il rischio che tali situazioni si verifichino.
Installation must be carried out following the local installation norms by qualified personnel.
The manufacturer refuses any responsibility when changes or unauthorized repairs are made to the product/system.
It is recommended to test the operation of the alarm product/system at least once a month. Despite frequent testing and due to, but not limited to,
any or all of the following: tampering, electrical or communication disruption or improper use, it is possible for the product/system to fail to prevent
burglary, rubbery, fire or otherwise. A properly installed and maintained alarm system can only reduce the risk that this happens.
www.amcelettronica.com
VISTA IN PIANTA
JP1= doubble pulse
JP2 = Walk test led
ALARM = alarm contact
AP = tamper contact
SUPPLY = power supply 13.8Vcc
SMILE 19 Pir Detector
2
45°
45°
JP1= doppio impulso
JP2 = Walk test led
ALARM = contatto allarme
AP = contatto tamper
SUPPLY = alimetazione 13.8Vcc
9 to 15 Vcc
(18 mA/9.5mA) @ 13.8 Vcc
15 mt
90°
2 elementi / 2 elements
29 patterns on 5 levels
0.2 A - 24 Vcc
Max 40 mA - 30 Vcc
From -10 °C to +55 °C
30 V / m (20 MHz - 2000 MHz)
ABS
110 x 60 x 46 mm
Installation Instructions v1.1
SMILE 19 permette una
copertura di 15 mt, la
speciale
conformazio-
ne della lente permette
un'apertura
orizzontale
di oltre 90° con 29 fasci
su 5 livelli
SMILE 19 allows a ran-
ge of 15 mt, the special
lens shape provides a
horizontal coverage
of
more than 90° with 29
patterns on 5 levels.