3 PRODUCT DESCRIPTION

3.1 GENERAL DESCRIPTION

The AMC-2751 sensor/transmitter unit is designed to provide continuous, reliable surveillance of
surrounding air for the target gas listed in the Factory Settings (Section 2.2). This unit provides
a 4 to 20 mA, variable current signal, which is proportional to the gas concentration detected.
Each sensor/transmitter unit is factory calibrated, and is ready for field installation and
operation.

3.1.1 SENSOR / TRANSMITTER SPECIFICATIONS

SENSOR ORDER NUMBER
SENSOR TYPE & GAS:
GAS RANGES
SENSOR RESPONSE TIME:
EXPECTED SENSOR LIFE:
SENSOR/TRANSMITTER
OPERATING TEMPERATURE:
SENSOR/TRANSMITTER
HUMIDITY RANGE:
SENSOR/TRANSMITTER SIGNAL: 4 to 20ma
SIGNAL LINEARITY:
AMC-2751 Transmitter & Sensor
AMC 91AG
Electrochemical cell for carbon monoxide.
0-100 ppm CO
0-300 ppm CO
Better than 90% step change in 45 seconds @ 20ºC
Greater than 4 years
-20ºC to 40ºC
15 to 90% RH, non-condensing (constant)
0 to 98% RH, non-condensing (intermittent)
Linear to the concentration of gas
5
□,
□,
0-200 ppm CO
□,
0-400 ppm CO