FLO-DYNAMICS CMS-120 Quick Start Instructions - Page 8
Browse online or download pdf Quick Start Instructions for Industrial Equipment FLO-DYNAMICS CMS-120. FLO-DYNAMICS CMS-120 8 pages. Coolant management system
40201194
CMS-120
QUICK START
Coolant Management System
INSTRUCTIONS
REMOVE COOLANT FROM A VEHICLE'S EXPANSION / DE-GAS BOTTLE
Move the Flow Control to "OFF" and connect shop air to
the machine.
Close the ball valve on the black service hose and connect
the open-end adapter.
Turn Tank Control and Vacuum Control to YELLOW and
Assist Control to VENT.
Move the Flow Control to "ON" until the desired coolant
level is reached.
Move the Flow Control to "OFF" and turn Tank Control
and Vacuum Control to VENT.
Close the ball valves and remove the service hoses.
Flo-Dynamics, Inc. • 3300 Reedy Drive • Elkhart, IN 46514 • 800-303-5874
Page 8 of 8