AMCOL 6000E Operator's Manual - Page 6

Browse online or download pdf Operator's Manual for Controller AMCOL 6000E. AMCOL 6000E 19 pages. Electronic timing controller for forming and fabricating
Also for AMCOL 6000E: Operator's Manual (6 pages)

AMCOL 6000E Operator's Manual

4 Recommended Settings

B
C
A
System
Air In
Item ID
Description
A
System Air Pressure
B
Injection Pulse Rate Solenoid
C
Dispersing Air Solenoid
D
Dispersing Air Pressure
E
Injection Volume

Settings with SMART Metering

All 6000E systems include a dual solenoid control package that eliminates the
variability of traditional pneumatic controls. Fixed position hex caps and non-
adjustable regulators remove variability associated with spray volume and pattern.
Fixed hex caps use set screws and epoxy to lock the distance of the
adjustment screw inside the hex cap. This allows for a consistent, minimal fluid
output to remove variability in spray volume.
Nonadjustable regulators remove the variability in adjustable regulators,
allowing for a consistent spray pattern at the spray point.
Using a combination of SMART Metering components, all variability of a 6000E
system can be remove, allowing the spray volume to be solely based on injection
rate of the T60A pump.
6000E ELECTRONICALLY CONTROLLED PRECISION LUBRICATION SYSTEM
Air
Liquid
D
Air Out
To Spray Point
Recommended Setting
60 PSI
According to machine cycle rate and volume
According to machine cycle rate
20 PSI as a starting point. Adjustment of the flow
control at the transition block is highly
dependent on spray tip. Adjust as needed, DO
NOT mist or fog!
Start at 1.5 turns open from off (fixed injection
volume is also available)
Operator's Manual
Liquid Out
To Spray Point
E
P A G E | 5