Too Much Liquid
T60A adjustment screw is too far open: adjust clockwise.
•
Not Enough Liquid
Too far closed: adjust counterclockwise
•
Liquid outlet (or hose) is kinked: replace.
•
Liquid Volume is Inconsistent
Injector is contaminated: clean.
•
O-ring seal is faulty: replace or rebuild.
•
Liquid Volume is Increasing with Time
O-ring on adjustment stem is deteriorated: replace.
•
Liquid Leaking from Pump Body
O-ring seals are worn: replace.
•
Piston sleeve is not tight: tighten.
•
Piston sleeve is worn: rebuild complete injector
•