WATER-DRAINAGE
1. Manual drainage
1.1 When the internal water tank is full the unit will stop working.
1.2 Shut off the unit and unplug. Try not to move the model abruptly as this may
cause water to spilt out from internal water tank.
1.3 Place a tray under the water plug.
1.4 Screw off the Drain plug cap and unplug the rubber stopper - water will drain from the container.
1.5 Put the water blocker back and screw the water plug back into place.
2. Continuous drainage:
2.1 Screw off the Drain plug cap and unplug trubber stopper.
2.2 Use a water pipe to connect to the water outlet to remove the water
out continuously.
Note: This model has a self-evaporative function, which reduces the need
to empty the water tank.
If the unit is vented correctly most of the water is reused to cool the
condenser coils and any excess is evaporated.
Please do not use continuous drainage if you intend to use
the self-evaporating facility.
MAINTENANCE
Cleaning
Please shut off the unit and unplug from the mains before cleaning or performing any maintenance.
Clean the surface
Clean the plastic housing with a duster or a soft wet cloth.
Do not use chemical solvents (such as benzene, alcohol or gasoline) as they may cause
irreversible damage.
Air filter cleaning
a) Clean the air filters every 2 weeks. If the air filter is blocked with dust, the unit's performance
will be significantly affected.
b) Pull out the top and bottom filters as pictured below
c) Wash the air filters by immersing them in warm (about 40℃) water with a neutral detergent.
d) Rinse it and then dry it thoroughly.
e) Carefully re-install air filters
End of Season Maintenance
1. Pull out the plug from the drainage hole and empty the internal tank. You can also drain the
water by leaning the unit.
2. Then switch the unit to Fan mode, and hold the button down for 5 seconds until it reaches
a low fan speed.
3. Keep the unit in this mode for half day - until the conduit is dried. Doing this helps to keep the
inside of the unit dry and prevents mold developing
4. Turn off the unit and pull out the plug.
5. Coil the wire and bind it together, then put it into the accessories space.
6. Separate the air-exhausted pipe and store it safely.
7. Cover the unit and keep it in a dry place.
8. Take the batteries out of remote control and store, or dispose, them safely
8
8
Drain plug cap
Rubber stopper
Drain connector
Drain plug cap
Drain pipe (size: 10 mm)