ACR STOVES FB5BK Technical Manual - Page 2
Browse online or download pdf Technical Manual for Wood stove ACR STOVES FB5BK. ACR STOVES FB5BK 10 pages.
Important!
To ensure that you gain the most from your purchase, please
take a few minutes to read through this manual before lighting
the appliance for the first time.
Before installation, please ensure that the correct model has been supplied.
Please make a note of the serial number of your appliance in the space
provided on the front cover of this manual as this will be requested if you
require technical assistance in the future.
Please also ensure that the commissioning checklist at the rear of the manual
is completed in full.
Since April 2002 only registered competent installers can install solid fuel
appliances. Installations carried out by non-registered installers must be
inspected by local authority building control.
For more information please contact hetas at: www.hetas.co.uk or
telephone: 0845 6345626
• The installation of this appliance must
comply with current Building
Regulations and local regulations,
including those referring to national
and European standards.
• Do not operate this appliance if it
becomes damaged.
• Improper use, maintenance or fitting
parts other than those approved by
the manufacturer could lead to the
appliance becoming damaged or
unsafe which in turn could lead to
personal injury or damage to the
property and will void the warranty.
• The appliance must not be modified in
anyway unless authorised by ACR
Heat Products Ltd.
• The appliance should be inspected
regularly to ensure the airways are
clean and free from obstruction and
the chimney swept at least once a
year.
• The external surfaces of this
appliance will be very hot to the touch
when in operation and due care will
need to be taken when operating the
appliance to ensure safety. A fire
guard should be fitted if it is likely that
the elderly, infirm or children may
come into contact with the appliance.
• This appliance must not be used as
an incinerator.
• This appliance has been designed for
intermittent operation.
Tenbury Specifications
Nominal heat output
Chimney draft required
Height
Width
Depth
Weight
Air Requirement
Flue Mass Gas Flow
2
CO @ 13% O
Mean Flue Gas Temperature
Efficiency
Log Length
Hearth Temperature
800
725
DO NOT INSTALL IN A ROOM CONTAINING AN EXTRACTOR FAN UNLESS
THE APPLIANCE HAS BEEN CORRECTLY TESTED IN ACCORDANCE
WITH BUILDING REGS DOC J
9 kW - Wood
12Pa
Up to 1590 mm
800 mm
475 mm
115 kg
220mm²***
8.7g/s - Wood
0.06 Wood Vol%
263°C - Wood
79.3% - Wood
Up To 450 mm
157ºC
500
*** Please note that Building
Regulations Document J
advises that additional
permanent air supply is
required for appliances with
an output of above 5Kw.
With modern properties
additional air may be
required as Document J
suggests that adequate air
would be a benefit.
• If design air permeability
≥5.0m³/ (h.m²) then
550mm²/kW of appliance
rated output above 5kW
Or
• If design air permeability
≤5.0m³/ (h.m²) then
550mm²/kW of appliance
rated output
• If in doubt, please consult
your registered installer
for advice.
475