12. MODULE WIRING
Each Module has two #12 AWG type standard 90°C sunlight resistant output cables each terminated with plug & ply
connectors. This cable is suitable for applications where wiring is exposed to the direct rays of the Sun. We
recommend that all wiring and electrical connections comply with local regulations.
For field connections, use the minimum No. #12 AWG copper wires insulated for a minimum of 90°C and sunlight
resistant as well. The minimum and maximum outer cable diameters of the cable are 5 to 7mm. Refer to table 1 for
the maximum electrical rating of series fuse.
13. TYPE OF PRODUCT APPLICATION
"The modules are qualified for application class A: Hazardous voltage (IEC61730: higher than 50V DC; EN61730:
higher than 120V), hazardous power applications (higher than 240W) where general contract access is anticipated
(Modules qualified for safety through EN IEC61730-1 and EN IEC61730-2 within this application class are
considered to meet the requirements for Safety class II)"
14. MAINTENANCE
Under most weather conditions, normal rainfall is sufficient to keep the SPV Module glass surface clean. If dirt
build-up becomes excessive, clean the glass only with a soft cloth using mild detergent and water. USE CAUTION
WHEN CLEANING THE BACK SURFACE OF THE MODULE TO AVOID PENETRATING THE SUBSTRATE
MATERIALS. SPV Modules that are mounted flat (0° tilt angle) should be cleaned more often, as they will not ''self
clean'' as effectively as Modules mounted at a 15° tilt or greater. Once a year, check the tightness of terminal screws
and the general condition of the wiring. Also, check to be sure that mounting hardware is tight. Loose connections
will result in damage for array. Changed SPV Module must be the same kind and type. Do not touch live parts of
cables and connectors. Use appropriate safety equipment (insulated tools, insulating gloves, etc.), when touching
them.
Cover the front surface of the SPV Module by an opaque or other material when repairing. The SPV Modules when
exposed to sunlight generate high voltage and are dangerous.
15. SPECIFICATIONS:
See Table1
Notes
1.
Standard Test Condition(STC) of Irradiance of 1000W/m²,AM1.5 Solar Spectrum & 25ºC cell temperature
2.
Nominal Operating Cell Temperature (NOCT): 45±2ºC
3.
The tolerance of Voltage and Current within ±10%
4.
Temperature coefficient of Current is 0.05%/ºK
5.
Temperature coefficient of Voltage is -0.30%/°K
6.
See SPV Module drawing for mounting and grounding holes locations. The drawing for CNPV-xxxxM and
CNPV-xxxxB(Black module) is identical.
Shengli Industry Park, Dongying City, Shandong Province 257000, PRC
http//www.cnpv-power.com
CNPV Dongying Solar Power Company Limited,
E-mail:
TECHNICAL SPECIFICATION
SPEC. NO.:
REVISION:
EFFECTIVE DATE:
Tel: +86-546-7795555, Fax: +86-546-7795777
CNPV-PS-M-S0010-IEC
J
July 2012
Page 6 of 15