AMD DIrect FPB-26SPSSF18TPSI-P Installation And Operating Instructions Manual - Page 14
Browse online or download pdf Installation And Operating Instructions Manual for Outdoor Fireplace AMD DIrect FPB-26SPSSF18TPSI-P. AMD DIrect FPB-26SPSSF18TPSI-P 20 pages. Square drop in pan fire pits with thermocouple piloted safety ignition (tpsi) & pro brass snowflake burner
1. The fire pit should be inspected and cleaned before initial use, at least annually, by a qualified field service person.
2. Any component that is found faulty must be replaced with an approved component.
3. Any tampering or modifying with the fire pit is dangerous and voids all warranties.
4. During winter months in cold climates and various seasons of operation the fire pit may be affected by weather
conditions. It is recommended to use a ventilated cover over top of your fire pit to protect it from humid/rainy weather
conditions when not in use. Heavy rains/downpours could affect the fire pit operation if not covered; if this occurs
ensure you allow the fire pit time to dry out before attempting to operate. NOTE: If a combustible type cover is used
over the fire pit when not in use be sure to remove it before operation to prevent a severe safety hazard.
5. Over time stainless steel parts can discolor when heated, usually a golden or brown hue. This discoloration is normal
and does not affect the performance of the appliance.
Brass Burner Maintenance Information:
•
Dust in injector - Use compressed air from aerosol can or compressor.
•
Check for bug nests or stubborn debris - replacement where necessary.
Note: Always use safety equipment including but not limited to SAFETY glasses or goggles when using
compressed air and consider a disposable mask for particulate.
Symptom
Remedy
Fire pit won't light
1. Bleed gas line.
2. Ensure all gas supply lines are turned ON.
3. Ensure there is not too much media over top of burner; it can inhibit gas from flowing.
4. Check gas pressure.
Low flame
1. Ensure the base media is at least 1-inch in diameter and top media is no more than 1-inch over
2. Ensure all shut-off valves and key valve is fully open. See page 9; Fig. 7
3. Check gas pressure.
Water in my fire pit
1. Excess dust/sand material from media may be blocking the weep holes to relieve water.
2. Remove all media and unplug weep holes. Clean or install new media free of dust and dirt.
3. Ensure fire pit enclosure has proper drainage for water and proper ventilation to dry out.
Sq. Drop In Pan Fire Pits with Snowflake Burner and (TPSI) Ignition
FIRE PIT MAINTENANCE
TROUBLE SHOOTING
top of burner and do not cover injectors.
REV. A
Page 14