AMD DIrect Pro Series Installation And Operating Instructions Manual - Page 4
Browse online or download pdf Installation And Operating Instructions Manual for Burner AMD DIrect Pro Series. AMD DIrect Pro Series 20 pages. Round drop in pan fire pits with thermocouple piloted safety ignition (tpsi) & pro brass snowflake burner
Also for AMD DIrect Pro Series: Installation And Operating Instructions Manual (20 pages), Installation And Operating Instructions Manual (20 pages), Installation And Operating Instructions Manual (20 pages)
MODELS
N = Natural
P = Propane
FPB-19RPSSF11TPSI-N
FPB-19RPSSF11TPSI-P
FPB-25RPSSF18TPSI-N
FPB-25RPSSF18TPSI-P
FPB-29RPSSF18TPSI-N
FPB-29RPSSF18TPSI-P
Table 1 Fire Pit Dimensions
*
Drop-In Pan
2 ½"
.875 TYP. (usable lip area)
Fig. 1 Burner pan specifications.
Pressure
Min. Inlet
3.5" WC (0.87 kPa)
Max. Inlet
10.5" WC (2.61kPa)
Normal Inlet 7.0" WC (1.74 kPa)
Table 2 Gas Pressures
Models:
Natural Gas
FPB-19RPSSF11TPSI-N
FPB-25RPSSF18TPSI-N
FPB-29RPSSF18TPSI-N
Table 3 Burner specifications.
Disclaimer: BTU listings are based on 7.0"WC for Natural Gas
and 11.0"WC for Liquid Propane (LP) at the burner orifice. Flex
line size and proper gas pipe sizing will also affect BTU's. As a
result your BTU's may vary slightly from Table 2 specifications.
Rd. Drop In Pan Fire Pits with Snowflake Burner and (TPSI) Ignition
SPECIFICATIONS
PAN
DIMENSIONS
OPENING SIZE
(I.D.)
19" Diameter (I.D.)
20" Diameter
(483mm)
26" Diameter
25" Diameter (I.D.)
(635mm)
28" Diameter
29" Diameter (I.D.)
(737mm)
O.D.
I.D.
8"
Ground Level (Earth)
NG
LP
8.0" WC (1.99kPa)
13.0" WC (3.23 kPa)
11.0" WC (2.73 kPa)
#
NG Injector
BTU
Jets
Size
Ratings
8
#61 (0.039)
50K
24
#61 (0.039)
145K
24
#61 (0.039)
145K
MAX.
BURNER
SIZE
11" Sq.
(508mm)
(279mm)
.
18" Sq
(660mm)
(457mm)
.
18" Sq
(711mm)
(457mm)
*
Fig. 2 Clearance to Combustibles for models.
(Not to be used in an enclosed space)
Models:
Propane Gas
FPB-19RPSSF11TPSI-P
(14.65kW)
FPB-25RPSSF18TPSI-P
(42.95kW)
FPB-29RPSSF18TPSI-P
(42.95kW)
CAUTION:
No LPK conversion kits are available for brass burners.
You must order the correct burner.
GROUND
SIDE
COMBUSTIBLE
LEVEL
WALL
CEILING
8"
36"
96"
(203mm)
(914mm)
(3048mm)
8"
36"
120"
(203mm)
(914mm)
(3048mm)
8"
36"
120"
(203mm)
(914mm)
(3048mm)
Combustible Ceiling
36"
Max
Overhang
C L
96/120"
36"
Combustible Floor
LP Injector
BTU
Size
Ratings
#72 (0.025)
#72 (0.025)
124K
#72 (0.025)
124K
COMBUSTIBLE
FLOOR
18"
(457mm)
18"
(457mm)
18"
(457mm)
18"
42K
(12.30kW)
(36.34kW)
(36.34kW)
REV. A