Acer AL1512 Service Manual - Page 11

Browse online or download pdf Service Manual for Monitor Acer AL1512. Acer AL1512 50 pages. Acer al1512m: installation guide
Also for Acer AL1512: Installation Manual (9 pages), Service Manual (50 pages)

Luminance of center point: L=L(5)
Brightness Uniformity Measurement points: Five specified points 1-5
Formula: Maximum [L (1), L (2), L (3), L (4), L (5)]/Minimum [L (1), L (2), L (3), L (4),
L (5)]
Note (3) Definition of Response Time (T
100%
90%
Optical
10%
Response
0%
Note (4)
Measurement Setup:
The LCD module should be stabilized at given temperature for 20 minutes to
avoid abrupt temperature change during measuring. In order to stabilize the
luminance, the measurement should be executed after lighting Backlight for
20 minutes in a windless room.
LCD Module
LCD Panel
Center of the Screen
, T
R
Gray Level 255
T
R
Field of View = 2º
500 mm
11
):
F
Gray Level 255
Gray Level 0
Photometer
(TOPCON BM-5A)
Light Shield Room
(Ambient Luminance < 2 lux)
T
F
Time