Aero-Spa AP 1000 Installation Manual - Page 10
Browse online or download pdf Installation Manual for Hot Tub Aero-Spa AP 1000. Aero-Spa AP 1000 13 pages.
Also for Aero-Spa AP 1000: Installation Manual (12 pages)
This is normal when the water used to fill the hot tub has high iron
content. Using "rust or stain remover" solution, wipe the rust stain with
damp sponge containing rust or stain remover. Rinse sponge in
solution periodically.
This occurs when the water used to fill the hot tub is hard. Using a
sponge or "Scouring pad" pad, wipe surface to remove scale. Care
should be used if using a "Scouring pad" pad to ensure the surface of
the hot tub is not damaged. Recommend use of calcium or scale
controller to lower Calcium Hardness
Light brown material on surface of hot tub walls
This occurs when the water is not adequately circulated in the hot tub.
Using a sponge, wipe surface to remove scale.
1. Increase hot tub circulation pump cycle time. Synchronize
circulation pump and Aero-Spa run time.
Water is normally clear but turns cloudy during or just after use
1. Increase the cycle run time by 25%
2. If these steps do not solve the problem within (4) days,
contact Aero-Spa, LLC
Water back siphoned into the ozone tube and or the ozone
1. A small amount of moisture can be considered normal in high
humidity conditions and in such a case nothing needs to be
done. If there is more than a few drops proceed to step 2.
below
2. Turn off all power by unplugging Aero-Spa from the 120 volt
power outlet. Remove the sintered diffuser from the hot tub
and lay it on the ground at a lower elevation than the
generator. Allow the unit to purge the water from the ozone
tube. When complete, reinstall sintered diffuser in hot tub
and make sure the air line is installed as described in the
installation procedure.
3. If these steps do not solve the problem call Aero-Spa, LLC
Brown ring at water line
Light scale on surface
generator
10
© Copyright Aero-Spa®, LLC 2021 REV H