UNPACKING

• Do not remove protective packaging until you are ready to perform the installation.
• Do not remove the protective wrapping from the product control panel until the product is installed.
• Caution - the appliance is heavy. Use extreme care when handling!
• Use proper equipment to move products.
• Any openings in the wall and in the floor behind or under the oven must be sealed.
• Do not use an extension cord with this appliance. Such use may result in fire, electrical shock or other personal injury.
• Installation of this appliance should be performed by qualified, licensed contractors.
• Carefully disassemble the wooden crate.
• Confirm access to adequate power and gas. See specifications & electrical requirements table.
• Fill out the inside cover of this installation manual with the requested data. Model Number and Serial Number can be
found on the plate located inside the kick plate.

POSITIONING

Although the sharp edges of metal parts are deburred during manufacture, accidents could occur if the Heavy Duty Range should
move suddenly while being pushed into position by hand. Pushing a unit (rather then using a lift jack) also increases the probability
of bending the leg spindles. Do not push against the edges of the unit in an attempt to adjust its position. Lift it slightly and place it
where it is being installed.

LEvELING

A carpenter's spirit level should be placed on the oven's center baking rack, and the unit leveled both front-to-back and side-to-
side. If the unit is not level, cakes, casseroles and any other liquid or semi-liquid batter will not bake evenly, burner combustion may
become erratic, and the unit will not function properly.
If the floor is relatively smooth and level, the unit may be leveled by turning the "foot" section of the leg, since casters are not
adjustable. Identify the high corner and level the unit - using metal shims if the adjustment amount required exceeds the 1-1/4"
adjustment amount available. Casters must be leveled with shims. A unit on casters will probably not return to the same position
after being moved, so be sure to re-level as necessary.

GAS SUPPLY

The gas connection is made at the left, right or rear of the equipment. The size of the pipe work supplying the
appliance must not be less than the inlet connection, which is 1-1/4" NPT. (Note: A 3/4" NPT single unit optional connection
must be specified.) An isolating valve is recommended to be close to the appliance to allow routine servicing or shutdown during
an emergency.
Be sure to check the complete pipe work for gas leakage.