4
5
6
Hi
Lo
COF
ddis
Fdis
udiS
Firm
* only models with 2nd switching contact
** only models with analog output
(ASP = 0,0% - 80,0% Span, AEP = 20,0% - 100% Span; ASP = AEP – 20% Span)
*** setting according to measuring range
Lock
Lock
Display
+
5 sec.
10
Factory setting
Maximum
peak value
Delete
Minimum
peak value
Delete
Offset (10 %
of measuring
range)
Damping
0... 50 s
0 s
display
Function
norm. –
norm.
display
rot.
Unit indication
ON - OFF
OFF
Firmware
version
Software
On - Off
Off
lock
8
Maintenance/Cleaning
Maintenance
The pressure switch requires no maintenance.
WARNING
Check the switch for functioning at regular intervals.
If the switch does not work properly, stop operation immediately.
Cleaning
CAUTION
The switch may be damaged by the use of unsuitable cleaning agents.
The following cleaning agents may be used to clean polycarbonates:
- Mild soap or detergents
- Isopropyl alcohol
After cleaning, immediately rinse with water. Do not leave cleaners on surfaces of products.
Do not clean products at elevated temperatures or under direct sunlight.
The following cleaning agents are known to affect the integrity of polycarbonate components and
should not be used:
- ZEP Fast 505, Pinesol, Formula 409
- Brake Cleaner
- Halogenated solvents (benzene, gasoline, acetone or carbon tetrachloride)
- Strong alkaline
- MEK (methyl ethyl ketone)
- Abrasive substances
9
Decommissioning
DANGER
Only remove the switch when deenergized (electrically and hydraulically/pneumatically).
Reduce the low pressure first, followed by the high pressure.
Disconnection of the switch from pressure and power supply must be carried out by trained or
instructed personnel according to state-of-the-art standards.
WARNING
Be aware of the fact that in case of operation with higher temperatures the casing surface may
become very hot!
11