Barksdale Dynalco SST7400 Installation And Operation Manual - Page 14
Browse online or download pdf Installation And Operation Manual for Switch Barksdale Dynalco SST7400. Barksdale Dynalco SST7400 19 pages. Speed switch / transmitter
![Barksdale Dynalco SST7400 Installation And Operation Manual](/uploads/products/server2/1089205/1089205.jpg)
Analog Output
The analog output tab is used to define the RPM range of the proportional 4 – 20 mA output.
RPM Zero
o Set to the RPM value corresponding to 4 mA output.
o Normally set to 0 RPM but can be set to any value as long as it is lower than
the RPM span.
RPM Span
o Set to the RPM value corresponding to 20 mA output.