Euro-Pro EP621H Owner's Manual - Page 3
Browse online or download pdf Owner's Manual for Vacuum Cleaner Euro-Pro EP621H. Euro-Pro EP621H 6 pages. Lightweight upright vacuum
OPERATING INSTRUCTIONS
Changing the Belt
WARNING:
Always disconnect
from power source when
servicing or cleaning the unit. Failure to
do so could result in electrical shock or
personal injury from cleaner suddenly
starting.
Occasionally the motorized brush drive
belt will require changing, the frequency
will depend upon the amount of use your
vacuum sees.
• Turn unit "Off" and unplug from
wall outlet.
• Remove the motorized floor brush
from the main unit. (see page 4)
• Use a Phillips #1 screwdriver and
remove the two (2) front screws
from the bottom of the motorized
floor brush. (Fig. 18)
Screws
Fig. 18
• Remove the brush cover. (Fig. 19)
Fig. 19
Fig. 20
• Remove the brush carefully by first
lifting the right side of the brush and
then the left side of the brush. Be
careful not to lose the end caps and
washers (x2). (Fig. 18)
• If the belt has broken, remove any
loose pieces of broken belt before
replacing with new belt.
• To install a new belt, slip one end of
the belt over the gears on the motor
shaft and then slip the other end
over the pulley end of the brush.
• After checking that the end caps
and washers are on correctly,
re-install the brush assembly.
• Turn the brush assembly by hand to
make sure that the belt is not
twisted and all rotating parts turn
freely.
• Replace the brush cover and
screws. (Fig. 21)
Fig. 19
Motor Thermostat
IMPORTANT:
This unit is equipped
with a motor protective thermostat. If
for some reason the vacuum cleaner
should overheat, the thermostat will
automatically turn the unit off. Should
this occur:
• Push the On/Off button once.
• Disconnect the plug from the
power source.
• Check the source of overheating
problem. (i.e. clogged hose or
filter)
• If clogged hose or filter is found,
unclog the hose and replace the
filters.
• Wait at least 45 minutes before
attempting to reuse the vacuum.
• After unit has cooled down for
45 minutes, plug in the cleaner
and push the On/Off button. The
vacuum should start again.
• If the vacuum still does not start,
contact customer service at
1 (800) 798-7398.
9
GETTING TO KNOW YOUR LIGHTWEIGHT
UPRIGHT VACUUM
1.
Hand Grip
2.
Hose/Power Cord Holder
3.
Flexible Hose
4.
Removable Hose Handle
5.
Exhaust Filter Cover
6.
Main Unit
7.
Dust Cup Container
8.
Dust Cup Release Lever
9.
Extension Tube
10. On/Off Switch
11. Lifting Handle
12. Crevice Tool
13. Dusting Brush
14. Motorized Floor Brush
15. Quick Release Cord Holder
16. Lower Cord Holder
17. Lower Hose Holder
18. Inlet Hose
19. Power Cord
20. Brush Roll Warning Light
21. Manual Variable Suction
Control
22. Trap Door Release Button
23. Intelli-Sense
TM
Filter Monitor
24. Hose Clip
Technical Specifications
Voltage:
120V., 60Hz.
Power:
12 Amps
2