In the event of an overtemperature, the source of this
NOTES:
condition should be determined and rectifi ed immediately.
Thermal protection shall not be used as a motor overload
device. A separate motor overload device must be provided
in accordance with NEC codes. DO NOT LET THE
PUMP CYCLE OR RUN IF AN OVERLOAD CONDITION
OCCURS !
Moisture Sensors: (Optional) - A normally open (N/O)
detector is installed in the pump seal chamber which will
detect any moisture present. It is recommended that this
detector be connected in series to an alarm device or the
motor starter coil to alert the operator that a moisture detect
has occurred. In the event of a moisture detect, check the
individual moisture sensor probe leads for continuity, (∞
resistance = no moisture ) and the junction box/control
box for moisture content. This situations may induce a
false signal in the moisture detecting circuit. If none of
the above tests prove conclusive, the pump(s) should be
pulled and the source of the failure identifi ed and repaired.
IF A MOISTURE DETECT HAS OCCURRED SCHEDULE
MAINTENANCE AS SOON AS POSSIBLE.
Wire Size - If additional cord is required consult a qualifi ed
electrician for proper wire size.