Always switch off power before servicing.
The electronic control fails to operate:
1. Verify electric power supply. Reset circuit or replace fuse if necessary.
2. Verify all electrical connections (including keypad connection).
3. Verify that the Ground Fault Circuit Interrupter (G.F.C.I.) has not tripped.
4. If the system has been functioning for quite some time, it is possible that the thermal
protection has shut off the motor. It is indicated to switch off the system and to wait
for at least 30 minutes before using it again. Verify that air is flowing through all jets.
If not; cover the jets with warm water, then switch system ON and OFF several
times. The air outlets should be cleared. If this is not sufficient, carefully knock on
the jet heads with the handle of a screw driver or a similar plastic tool while the
blower is running.
5. If you have added a keypad extension, make sure that it has been certified by the
manufacturer of the electronic control. It could be the cause of your problem.
The blower or pump never stops:
1. Verify that the blower is well connected to the control box.
2. Verify the keypad connection.
3. Verify that there is no water reaching electrical components under your bathtub.
Troubleshooting - Air System
5
754474-100 Rev. A