SCREEN DJUSTMENT FOR SCREENS WITHOUT
SETTING THE UP LIMIT POSITION
L
CAUTION: Do not allow the slat bar to wrap over the top of the roller when the screen is rolling into the case. The
screen could be damaged.
SCREEN TRAVELS INTO CASE TOO FAR:
Turn the up limit switch screw clockwise to decrease the amount of travel. Run the screen up to test the
stop position. If the screen does not stop properly, lower the screen about one foot and turn the limit
switch again. Repeat until the desired position is set.
SCREEN DOES NOT TRAVEL FAR ENOUGH INTO CASE:
Turn the up limit switch screw counterclockwise to increase the amount of up travel. Run the screen up to
test the stop position. If more travel is desired, lower the screen about one foot and adjust the limit switch
again. Repeat until the desired position is set.
COSMOPOLIT N
®
ELECTROL
CONTROL
120V WIRING DIAGRAM
WITH OPTIONAL BUILT-IN
LOW VOLTAGE CONTROL
WHITE (COMMON)
BLACK (HOT)
120VAC 60HZ
GREEN
GROUND–MUST BE
CONNECTED TO
BUILDING GROUND
ILT RJ9 PIN-OUTS
(TAB IS FACING UP)
IR or UP
BLACK
GND COMMON
RED
+5V
GREEN
DN or DATA
WHITE
®
INST LL TION FOR SCREENS WITH
MOTOR
GREEN
GROUND TO CASE
IMPORTANT NOTE: The wall switch is REQUIRED to make any limit
BUILT-IN LOW VOLT GE CONTROL
BUILT-IN LOW VOLT GE
OPTIONAL IR AND RF
REMOTE CONTROL
RJ9
RJ9
SPLITTER
DRY CONTACTS
switch adjustments, EVEN if a third party control
system is used. Therefore, it is advised to wire
the switch or provide a 4-conductor connection
that is accessible.
FIGURE 4
3
LOW-VOLTAGE WALL SWITCH
UP DN
GND +5V
UP
STOP
DOWN
3-POSITION
RJ9
SWITCH
FRONT
BACK