2.

Product Specifications

Gas, Oil, Hlectric, (mV and 24V), Heat Only, Cool Only or Heat2Cool Systems
3.

General Information

3.1

Overview

3.1
Overview
Teb . 0 2 fp a kl k-m o l do am m abib . H,. Ct ebom l pt at t ft e a
The 102 is a non-programmable 1H/1C thermostat with a 2"
2 ' 'afdft ai afpm iav.
digital display.

Contents

3.2
Contents
. -Tebom l pt at
— 1-Thermostat
2 -Pefiifm p pil t t ba ebaa m l r kt fkd pc o bt p
— 2-Phillips slotted head mounting screws
2 -Nvil k Dovt aii Akc el o p
— 2-Nylon Drywall Anchors
. -I kpt aiiat fl k Dr fab , UpboDr fab
— 1-Installation Guide / User Guide
Pub. No. 11HD23D1-1B-EN 09/2020
SPECIFICATION DESCRIPTION
Product Models
Product
Configurations
Maximum Number of Stages
Operating Temperature
Shipping Temperature Range
Input Power (DC)
Input Power (AC)
Wire Usage
System Modes
Fan Modes
Cooling Setpoint Temperature Range
Heating Setpoint Temperature Range
Temperature Display Range
Minimum Cycle Off Time Delay
Terminal Load
Operating Ambient
Shipping Temperature Range
THERMOSTAT APPLICATION GUIDE
Thermostat Applications
Part No. 37-7771002
American Standard 102 Non-Programmable Thermostat
ACONT102
102
Size
3-7/8" x 5-1/2" x 1-3/16" (HxWxD)
Heat / Cool
1H, 1C
32°I to 105°I (0 to .41°C) 2 90% UH Non Condensing
040°I to 150°I (040° to 66°C)
Two 1.5V AAA Alkaline
20 - 30 VAC, NEC Class ll, 50/60 HZ
18 AWG
Heating, Cooling, Off
Auto, On
45°I to 90°I, 1°I resolution
45°I to 90°I, 1°I resolution
4°I to 99°I, 1°I resolution
Compressor: 5 minutes, Indoor Heat; none
1.0A per terminal, 1.5A maximum all terminals combined
32°I to .105°I (0° to .41°C)
040°I to .150°I (040° to .65°C)
4.

Installation

4.1

Location

The 102 is designed for installation in climate controlled living
spaces. Place the unit in a central location with good circulation.
For proper temperature sensing, avoid exposing the 102 to heat
radiated from lamps, sun light, fireplaces or any other radiant heat
source.
Avoid locations close to windows, behind doors or alcoves with
poor air circulation, adjoining outside walls, or doors that lead to
the outside.
Select a location that prevents the 102 from being directly exposed
to air currents from supply registers or ceiling fans.
Mount the Control on a section of interior wall that does not
contain hot or cold water pipes or duct work.
Maximum Stages Heat/Cool
1/1
3