TROUBLESHOOTING FLOW CHARTS
UNIT DOES NOT FUNCTION
ARE EXTERNAL SUPPLY
STOPS OPEN?
YES
IS INTERNAL SUPPLY
STOP OPEN?
YES
REPEATED DOUBLE FLASH
ON SENSOR?
NO
RECONNECT BATTERY TO SENSOR.
DOES SENSOR FLASH FOR 5 SECONDS?
YES
REPLACE SOLENOID
WATER IS CONTINUOUSLY RUNNING
RECONNECT BATTERY TO SENSOR.
DOES SENSOR FLASH FOR 5 SECONDS?
YES
REPLACE SOLENOID
LOW FLOW ISSUES
ARE INTERNAL & EXTERNAL SUPPLY
STOPS FULLY OPEN?
YES
LOW FLOW COULD BE CAUSED BY DEBRIS
IN THE FILTER ASSEMBLY, FLOW REGULATOR
OR AERATOR/SPRAY. REMOVE, CLEAN AND
INSERT BACK TO ORIGINAL POSITION.
NO
OPEN EXTERNAL SUPPLY STOPS.
OPEN INTERNAL SUPPLY STOP.
NO
(HEX KEY NEEDED)
CRITICALLY LOW BATTERY.
YES
INSTALL NEW BATTERY.
1
1
NO
DEAD BATTERY. INSTALL
NEW BATTERY. REPEAT.
2
2
NO
CHECK FOR DAMAGE TO SENSOR WIRE INSULATION.
REPLACE SENSOR.
CHECK FOR DAMAGE TO SENSOR WIRE INSULATION.
NO
REPLACE SENSOR.
FULLY OPEN INTERNAL & EXTERNAL SUPPLY
NO
STOPS BY TURNING COUNTER CLOCKWISE.
Produ ct na m es l i s ted herei n are tradem ar ks of AS A m er i ca, In c . ©2 014
To learn more about American Standard Selectronic® Products visit our website at:
www.americanstandard-us.com or e-mail us at: [email protected]
9
HOT LINE FOR HELP
For toll-free information and answers to your questions, call:
(844) CRT-TEAM / (844) 278-8326
Weekdays 8:00 a.m. to 6:00 p.m. EST
IN MEXICO 01-800-839-1200
IN CANADA 1-800-387-0369 (TORONTO 1-905-306-1093)
Weekdays 8:00 a.m. to 7:00 p.m. EST
M965653 (11/14)