Fig. 3
Unit #1
Already installed
AC HARDWIRE
POWER SUPPLY
C
MULTI-AC VERSION (DAISY-CHAIN); Fig. 3, 3a
Important: All enclosure covers must be removed before beginning to make daisy-chain connections.
Disconnect the first unit's Y-Adapter from power supply before making daisy-chain connections.
Note: For Unit #1 electrical instructions, refer to section B (page 5).
For subsequent Units, refer to instructions below...
1. Remove COVERS from all ENCLOSURES (3).
2. Insert pervious unit's 10' EXTENSION (11a) through
gray GROMMET (5b) and connect to single terminal of
Y-ADAPTER (11).
3. Remove solid black plug grommet from left side of all
ENCLOSURES (3), and replace with GRAY
GROMMET (5b). (Supplied with each Faucet).
4. Feed 27" EXTENSION CABLES (2) through the top of
ENCLOUSURE (3). Connect one 27" EXTENSION
CABLE (2) to the SOLENOID CABLE (7), and the other
to either of the two terminals at the one end of the
Y-ADAPTER (11). Connect the current unit's 10'
EXTENSION (10a) to available terminal of the
Y-ADAPTER (11).
5. Feed the other end of the 10 ft.EXTENSION (10b)
through the two GRAY GROMMETS (6a and 6b) and
connect to the single terminal of the next unit's
Y-ADAPTER (11). Place Y-ADAPTER (11) into
ENCLOSURE (3).
6. Repeat Steps above for each additional Unit, for a
Max. of 15 Units on one AC POWER SUPPLY.
7. Replace ENCLOSURE COVERS. Tighten cover screws firmly.
CAUTION: Use only American Standard
supplied cable sets. Using non-AS supplied
cables, or cutting, splicing or modifying any
components will void the warranty.
AC POWER
SUPPLY
OR
Unit #2
*MAXIMUM OF 15 UNITS PER
AC POWER SUPPLY.
10' MAXIMUM CABLE
LENGTH BETWEEN UNITS.
Fig. 3a
3
10a
2
2
11a
5b
11
5
6
Unit #3
10 ft.
EXTENSION
CABLE
Unit #2 Detail
6a
7
M 9 6 5 6 5 2 ( 11 / 14 )
10b
6b