EKO MF Series Instruction Manual - Page 10

Browse online or download pdf Instruction Manual for Accessories EKO MF Series. EKO MF Series 20 pages. Heat flow sensor

Table 5-1.Installation Guide
Material of Installing Surface
Smooth metal
Rough metal (cast metal)
Tatami Mat
Curtain
Concrete (smooth surface)
Mortar (rough surface)
Grass wool molded plate
Wall Clay
Tuff
Wood, lumber
Pearlite plate
(Asbestos cement plate)
Tile or glass
Expanded Ply-Ethylene
Expanded Urethane
*Silicon grease with high thermal conductivity and bonding effect for temporary installation. Please see
section 7-3. Accessory section and/or contact EKO for more details and purchasing.
EKO INSTRUEMTNS CO., LTD. Heat Flow Sensors Instruction Manual Ver.7
Preparation
Degrease the surface by organic
solvent
Smooth out the surface as much as
possible.
Cut out or create a spot in advance for
embedding.
---
---
Smooth out the surface
Smooth out the surface as much as
possible.
Scrape the surface
Smooth out the surface as much as
possible.
Remember the direction of wood fiber
(sense of direction required)
Smooth out the surface as much as
possible.
Degrease the surface
Smooth out the surface as much as
possible
Installation Method
Attach with silicon grease or silicon glue
Embed inside the tatami mat.
Attach with silicon glue.
Embed with silicon glue or mortar.
Embed with mortar and even out the
surface roughness with surrounding
surface
Attach with silicon glue
Embed inside the surface or attach with
silicon glue
Attach with silicon glue
Attach with silicon glue
Attach with silicon glue
Attach with silicon grease or silicon glue.
Attach with silicon grease or silicon glue
Embed with expanded urethane
Pg. 9