American Weigh AMS-150 User Manual - Page 3
Browse online or download pdf User Manual for Scales American Weigh AMS-150. American Weigh AMS-150 4 pages. Pocket scale 150g x 0.1g
I. Operation
Place the scale on a horizontal flat surface.
1. Press ON/OFF key.
2. Wait until [0.0] is displayed.
3. Put the object(s) on the weighing platform.
4. Using the M key, you can switch between the weighing
modes.
II. Tare Weighing.
1. Turn on scale as described above.
2. Place the "tare item" on the platform.
3. Press T and wait until [0.0] is displayed.
4. Add the "net-weight-item".
III. Calibration
1. Press I/O key to reset the scale.
2. Press and hold the M and T buttons simultaneously until a
random number is displayed. Release the M and T buttons and
wait for the number to stabilize then press M. The display will
show "2Ero".
3. Place a 100g weight on the center of the platform. Wait two
seconds then press the M key again. The LCD will display
[PASS].
5. Remove the weight and turn off the scale.Calibration is
complete.