The above recommended times will also
be dependent on whether or not a
standard pool pump is being used or an
energy efficient variable speed pump.
3) IONS OUTPUT
IONS OUTPUT
SET FOR xxx mA
When you enter the IONS OUTPUT menu
you may change the current output for
ionisation, adjust according to copper
levels as determined by a water quality
test. Copper (Cu) should be in the range of
0.4 – 0.5 ppm. If the level of copper is
below 0.4 ppm then increase the current
output, if it is above 0.5 ppm then
decrease the current output, if it is above
0.6 ppm then set the current output to
0mA.
4) SEASON MODE
When the season mode menu is selected
the following is displayed;
SET SEASON MODE
SUMMER MODE/ WINTER MODE
SUMMER MODE is the normal operation of
filtration, 2 cycles per day. When selecting
WINTER MODE you will be prompted to
select the start month of winter and the
start month of summer. At the start of
nd
winter the 2
filter cycle is automatically
disabled to allow for reduce filtration
requirements in the off-season, when the
summer month start the 2
will automatically be re-applied. You can
also start winter mode in August and
finish in March if required (i.e. for Northern
Hemisphere). Hint: the two filter cycles
can be overlapped so if cycle 1 is from
PWP2_Instructions_rA1.docx
nd
filter cycle
10am-2pm and cycle 2 is from 8am to
4pm then in winter mode the time is
reduced by 2 hours at the start and end.
5) SYSTEM SETUP
When the system setup menu is selected 5
options are available;
SET CLOCK
INSTALLER SETUP
FACTORY DEFAULTS
RUNTIME LOGS
EXIT
SET CLOCK
– Allows you to adjust calendar
date and time of day.
EXIT
– Will return you to
SETUP
with no changes.
RUNTIME LOGS
pump and ionisation, NO support is offered for
this feature.
FACTORY DEFAULTS
the settings to the factory default state.
INSTALLER SETUP
contains the following advanced settings;
IONISE AT FILTER
TIMES ONLY? YES/NO
If you select 'YES' then ionisation will
always occur during filtration times and
you will skip the run hours menu as
described below, if 'NO' is selected then a
separate menu for run hours is displayed;
IONISING
RUN HOURS
hr:mn
If ionising at filtration times is producing
too much copper then you can adjust the
number of hours that ionisation occurs
during filtration times in one hour steps;
the maximum available time is calculated
from the filtration settings. This feature
will only be active from the start of the
next filtration cycle.
5) SYSTEM
– displays run times for
– Restores ALL
- This sub-menu
5