REPLACEMENT PARTS LIST
1
1
1
3
3
6
11
2
2 (4)*
1
1

TROUBLESHOOTING GUIDE

PROBLEM
Cloudy ice
cubes or milky
colored water.
Noisy drain or
faucet.
Hole on faucet
is leaking.
Filter bowl
canister leak.
11
07\15 RO Manual
805-25-04
805-15-04
124-462
127-1101
127-1R
805-LC-06
805-LC-04
122-321
122-24321
120-131
114-10
CAUSE
Bad membrane.
Water supply.
Refrigerator.
System is still new.
Air gap faucet.
Drain tube.
Drain clamp slipped.
Drain tube loops or
dips
Restriction in drain
tube.
O-ring not sealed
properly.
Faucet Adapter 3/8" × 7/16" fpt
¼" Union JG
Drain Saddle Clamp
Filter Bowl Canister
O-ring, Filter Bowl canister
3/8" Locking Clip JG
¼" Locking Clip JG
Clips, Membrane
Clips, Post Filter *(ET6000)
Bracket
Water Quality Monitor
SOLUTION
Replace Membrane and sanitize when below 75%
rejection
High oxygen content
Some refrigerators freeze differently, leaving the ice
cube looking cloudy. Let cube dissolve in glass of water.
If just air, will float to surface and dissipate.
This is normal and should clear up in two weeks.
A little noise is common with air gap faucets. Check
manual to be sure installed in proper location. Allow two
weeks for air to work out of system.
Check that drain tube from faucet is continuously down
hill to drain. Loops or dips will cause noise. Disconnect
drain tube and clean free of debris.
Align drain clamp hole with drainpipe hole.
Shorten drain tube from faucet until smooth down hill
flow to drain.
Disconnect drain tube and clean out restriction.
If damaged, replace. If dirty, clean, lubricate and re-
tighten filter bowl. Hand tighten firmly.