Akuvox R29 Series User Manual - Page 6
Browse online or download pdf User Manual for Control Unit Akuvox R29 Series. Akuvox R29 Series 16 pages. Lte module
Also for Akuvox R29 Series: User Manual (16 pages), User Manual (12 pages), Installation Manual (6 pages)
1.2. Connector Introduction
Ethernet (POE): Ethernet (POE) connector which can provide both
power and network connection.
12V/GND: External power supply terminal if POE is not available.
WG_D0/1: Wiegand terminal for wiegand access control.
RS485A/B: RS485 terminal for automation system control (e.g.
Figure 1.2-1 Connection introduction
Elevator control).
DOORA/B/C: Trigger signal input terminal (e.g. Press indoor
button to open relay).
RelayA/B/C: NO/NC Relay control terminal.
Note: The general door phone interface diagram is only for
reference.
Figure 1.2-2 General interface
2